1.rated current up to10A 16A;20A;25A;32A ;40A;63A
2.breaking capacity(A):10000,6000.4500
3.rated voltage:230/400v
4.mechanical life,more 20000
Temperature:-5 degree c-+40 degree c; the average value within 24h shall not exceed +35 degree ;
for the circuit breaker with themo-magnetic relaese,+40 degree is set to be the standard temperature for ratings,special utilization.
1.rated current up to1A-40A, 63A
2.breaking capacity(A),6000.
3.mechanical life,more 20000
Temperature:-5 degree c-+40 degree c; the average value within 24h shall not exceed +35 degree ;
for the circuit breaker with themo-magnetic relaese,+40 degree is set to be the standard temperature for ratings,special utilization.
1.rated current up to1A-40A, 6A, 10A, 16A, 20A, 32A
2.breaking capacity(A),6000.
3.mechanical life,more 20000
Temperature:-5 degree c-+40 degree c; the average value within 24h shall not exceed +35 degree ;
for the circuit breaker with themo-magnetic relaese,+40 degree is set to be the standard temperature for ratings,special utilization.
Circuit breaker Operated Circuit Breaker with over-current protection (Electronic)
General rules for choosing RCBO:
Rated residual operating current In 30 mA: additional protection in the case of direct
contact In 300 mA: preventative fire protection in the case
of ground fault currents
b.Tripping class AC class Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
c.Tripping curve
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
D curve (10-14 In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps).
SPEC:
| Standard | IEC/EN 60898-1 | ||
|
Electrical features |
Type (wave form of the earth leakage sensed) | AC | |
| Thermo-magnetic release characteristic | C, D | ||
| Rated current In | A | 63 | |
| Rated voltage Ue | V | 230/400 | |
| Rated sensitivity In | A | 0.03, 0.1, 0.3 | |
| Rated residual making and breaking capacity Im |
A |
500 |
|
| Rated short-circuit capacity lcn | A | 4,500/6,000 | |
| Break time under In | s | 0.1 | |
| Rated frequency | Hz | 50/60 | |
| Rated impulse withstand voltage (1.2/50)Uimp |
V |
4,000 |
|
| Dielectric TEST voltage at ind. Freq. for 1min | kV | 2 | |
| Insulation voltage Ui | 500 | ||
| Pollution degree | 2 | ||
|
Mechanical features |
Electrical life |
2,000 |
|
| Mechanical life | 2,000 | ||
| Contact position indicator | Yes | ||
| Protection degree | IP20 | ||
| Ambient temperature
(with daily average35C) |
C |
-5…+40 (Special application please refer to P72 for temperature compensation correction) | |
| Storage temperature | C | -25…+70 | |
|
Installation |
Terminal connection type | Cable/U-type busbar/Pin-type busbar | |
|
Terminal size top/bottom for cable |
mm2 | 25 | |
| AWG | 18-3 | ||
|
Terminal size top/bottom for busbar |
mm2 | 25 | |
| AWG | 18-3 | ||
|
Tightening torque |
N*m | 2 | |
| In-Ibs. |
18 |
||
| Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | ||
| Connection | From top | ||
Circuit breaker Temperature derating
| Temperature | -15C | -5C | 0C | 10C | 20C | 30C
1.00 |
40C | 55C |
| Temperature compensation coefficient |
1.19 |
1.15 |
1.13 |
1.06 |
1.05 |
0.96 |
0.89 |
Circuit breaker Operated Circuit Breaker with over-current protection (Electronic)
General rules for choosing RCBO:
Rated residual operating current In 30 mA: additional protection in the case of direct
contact In 300 mA: preventative fire protection in the case
of ground fault currents
b.Tripping class AC class Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
c.Tripping curve
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
D curve (10-14 In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps).
SPEC:
| Standard | IEC/EN 60898-1 | ||
|
Electrical features |
Type (wave form of the earth leakage sensed) | AC | |
| Thermo-magnetic release characteristic | C, D | ||
| Rated current In | A | 6, 10, 16, 20, 32, 40 | |
| Rated voltage Ue | V | 230/400 | |
| Rated sensitivity In | A | 0.03, 0.1, 0.3 | |
| Rated residual making and breaking capacity Im |
A |
500 |
|
| Rated short-circuit capacity lcn | A | 4,500/6,000 | |
| Break time under In | s | 0.1 | |
| Rated frequency | Hz | 50/60 | |
| Rated impulse withstand voltage (1.2/50)Uimp |
V |
4,000 |
|
| Dielectric TEST voltage at ind. Freq. for 1min | kV | 2 | |
| Insulation voltage Ui | 500 | ||
| Pollution degree | 2 | ||
|
Mechanical features |
Electrical life |
2,000 |
|
| Mechanical life | 2,000 | ||
| Contact position indicator | Yes | ||
| Protection degree | IP20 | ||
| Ambient temperature
(with daily average35C) |
C |
-5…+40 (Special application please refer to P72 for temperature compensation correction) | |
| Storage temperature | C | -25…+70 | |
|
Installation |
Terminal connection type | Cable/U-type busbar/Pin-type busbar | |
|
Terminal size top/bottom for cable |
mm2 | 25 | |
| AWG | 18-3 | ||
|
Terminal size top/bottom for busbar |
mm2 | 25 | |
| AWG | 18-3 | ||
|
Tightening torque |
N*m | 2 | |
| In-Ibs. |
18 |
||
| Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | ||
| Connection | From top | ||
Circuit breaker Temperature derating
| Temperature | -15C | -5C | 0C | 10C | 20C | 30C
1.00 |
40C | 55C |
| Temperature compensation coefficient |
1.19 |
1.15 |
1.13 |
1.06 |
1.05 |
0.96 |
0.89 |
dz47le earth leakage mini circuit breaker Operated Circuit Breaker with over-current protection (Electronic)
General rules for choosing RCBO:
Rated residual operating current In ≤ 30 mA: additional protection in the case of direct
contact In ≤300 mA: preventative fire protection in the case
of ground fault currents
b.Tripping class AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
c.Tripping curve
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
D curve (10-14 In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps).
dz47le earth leakage mini circuit breaker SPEC:
| Standard | IEC/EN 60898-1 | ||
|
Electrical features |
Type (wave form of the earth leakage sensed) | AC | |
| Thermo-magnetic release characteristic | C, D | ||
| Rated current In | A | 6, 10, 16, 20 , 32 | |
| Rated voltage Ue | V | 230/400 | |
| Rated sensitivity In | A | 0.03, 0.1, 0.3 | |
| Rated residual making and breaking capacity Im |
A |
500 |
|
| Rated short-circuit capacity lcn | A | 4,500/6,000 | |
| Break time under In | s | ≤0.1 | |
| Rated frequency | Hz | 50/60 | |
| Rated impulse withstand voltage (1.2/50)Uimp |
V |
4,000 |
|
| Dielectric TEST voltage at ind. Freq. for 1min | kV | 2 | |
| Insulation voltage Ui | 500 | ||
| Pollution degree | 2 | ||
|
Mechanical features |
Electrical life | 2,000 | |
| Mechanical life | 2,000 | ||
| Contact position indicator | Yes | ||
| Protection degree | IP20 | ||
| Ambient temperature
(with daily average≤35°C) |
°C |
-5…+40 (Special application please refer to P72 for temperature compensation correction) | |
| Storage temperature | °C | -25…+70 | |
|
Installation |
Terminal connection type | Cable/U-type busbar/Pin-type busbar | |
|
Terminal size top/bottom for cable |
mm2 | 25 | |
| AWG | 18-3 | ||
|
Terminal size top/bottom for busbar |
mm2 | 25 | |
| AWG | 18-3 | ||
|
Tightening torque |
N*m | 2 | |
| In-Ibs. | 18 | ||
| Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | ||
| Connection | From top | ||
dz47le earth leakage mini circuit breaker Temperature derating
| Temperature | -15°C | -5°C | 0°C | 10°C | 20°C | 30°C
1.00 |
40°C | 55°C |
| Temperature compensation coefficient |
1.19 |
1.15 |
1.13 |
1.06 |
1.05 |
0.96 |
0.89 |
1. Compliant standards
IEC61009-1
2. Compliant certification
CE
3. Major function
Overload protection, short circuit protection, isolation, residual current operation
4. Technical parameters
Rated current: 6A, 10A, 16A, 20A, 32A, 40A
Rated residual operating current: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A;
Rated voltage: 240V ~ 2P
Frequency: 50Hz;
Electromagnetic release type: B, C, D;
Number of poles: 2P
Mechanical life: 20000 cycles;
Electrical life: 10000 cycles;
Rated short-circuit breaking capacity(Icu): 6000A;
Short-circuit breaking capacity(Ics): 6000A;
Rated impulse withstand voltage(Uimp): 4kV;
Attomat RCBO CHINT NXBLE-63 3P+N C40,63
1. Đặc điểm chung
– Aptomat RCBO NXBLE-32 đạt tiêu chuẩn: CE
– Sản xuất theo tiêu chuẩn: IEC/EN61009-1
– Dải dòng: 40A, 63A
– Độ nhạy định mức: 30mA, 50mA, 75mA, 100mA, 300mA
– Dải điện áp: 240V ~ (1P+N, 2P), 415V ~ (3P, 3P+N, 4P)
– Đường cong đặc tính loại C (Đối với đường cong B và D vui lòng liên hệ với chúng tôi)
– Số cực: 3P+N,
– Khả năng cắt ngắt mạch Icu = Ics: 6000A
– Tuổi thọ cơ học lên đến 20,000 lần
– Tuổi thọ điện và cơ học lên đến 10,000 lần
– Bảo vệ chống quá tải, ngắn mạch
– Bảo vệ chống rò điện
– Cờ báo trạng thái hoạt động và trạng thái TRIP
– Nút Test và nút Reset thiết bị
– Lắp đặt cố định nằm ngang trên thanh rail 35mm
– Hiệu quả cao, chi phí tiết kiệm
Ứng dụng:
– Bảo vệ và ngắt điện trong mạng lưới điện dân dụng và văn phòng…
– Dùng trong các mạch điều khiển trong hệ thông công nghiệp
– Dùng bảo vệ động cơ …
2. Thông số kỹ thuật Attomat RCBO NXBLE-63 3P C63
– Attomat chống giật RCBO loại NXBLE
– Số cực: 3P
– Dòng định mức: 40A ,63A
– Dòng rò: 30mA (dòng rò khác liên hệ với chúng tôi)
– Điên áp (V) : AC 240V 50/60Hz
– Công suất cắt Icu=Ics: 6000A
Attomat RCBO CHINT NXBLE-63 3P+N C40,63
1. Đặc điểm chung
– Aptomat RCBO NXBLE-32 đạt tiêu chuẩn: CE
– Sản xuất theo tiêu chuẩn: IEC/EN61009-1
– Dải dòng: 40A, 63A
– Độ nhạy định mức: 30mA, 50mA, 75mA, 100mA, 300mA
– Dải điện áp: 240V ~ (1P+N, 2P), 415V ~ (3P, 3P+N, 4P)
– Đường cong đặc tính loại C (Đối với đường cong B và D vui lòng liên hệ với chúng tôi)
– Số cực: 3P+N,
– Khả năng cắt ngắt mạch Icu = Ics: 6000A
– Tuổi thọ cơ học lên đến 20,000 lần
– Tuổi thọ điện và cơ học lên đến 10,000 lần
– Bảo vệ chống quá tải, ngắn mạch
– Bảo vệ chống rò điện
– Cờ báo trạng thái hoạt động và trạng thái TRIP
– Nút Test và nút Reset thiết bị
– Lắp đặt cố định nằm ngang trên thanh rail 35mm
– Hiệu quả cao, chi phí tiết kiệm
Ứng dụng:
– Bảo vệ và ngắt điện trong mạng lưới điện dân dụng và văn phòng…
– Dùng trong các mạch điều khiển trong hệ thông công nghiệp
– Dùng bảo vệ động cơ …
2. Thông số kỹ thuật Attomat RCBO NXBLE-63 3P C63
– Attomat chống giật RCBO loại NXBLE
– Số cực: 3P
– Dòng định mức: 6A , 10A , 16A , 20A , 32A
– Dòng rò: 30mA (dòng rò khác liên hệ với chúng tôi)
– Điên áp (V) : AC 240V 50/60Hz
– Công suất cắt Icu=Ics: 6000A
Thông số RCBO NXBLE series Chint
Thông tin sản phẩm
Model: NXBLE-3PN-63/30
Thông số kỹ thuật:
Điều kiện hoạt động:
Kích thước: 36x77x76.8
YBLX-K1 series of travel switch is applicable to electric circuit with voltage and current for travel control, direction of motion or speed change of movement mechanism, automatic control, motion direction or speed change of machine tool, automatic control, action limit & travel or procedure control of movement mechanism.
| Product name: | Open Lug |
|---|---|
| Item: | OT sreies |
| Type: | Ring Terminals |
| Packaging: | OPP Bag |
| Description: | OT Terminal |
| Material: | Pure Red Copper |
| size: | 10A 20A 30A 40A 50A 60A 80A 100A 150A 200A 250A 300A 400A 500A 600A 800A 1000A |
| Thickness: | Different Current Different Thickness |
| Shape: | U |
| Character: | None |
| Specification: | Industrial |
Product description
The cable tracker consists of a transmitter and a receiver.
The transmitter provides a modulated AC voltage
The receiver is equipped with a coil.
The coil will generate very little pressure
The receiver’s electronic circuitry calculates the voltage and displays it on the display.
Application and Feature
-Find the Beaks or Shorts in Cable in the wall or Earth
-Track Cables in the wall or Earth
-Find the Fuse and Safeguard
-Find the Beaks or Shorts in Conduit under the Floor
-Track a Metal Conduit in the Project of ware or hot
-Sensitivity of Receiver can be selected
-Auto Ranging,Auto Power Off,Backlight and Worklight
16 results