Digital Only
Measuring Current Range:
AC 200A
Measuring Voltage Range:
1000V
Measuring Resistance Range:
2000 Ω 20.00kΩ 100.0kΩ
Operating Temperature:
-10°C-+50°C
Dimensions:
61.1mm*259.3mm*43.8mm
Weight:
0.35kg
Product name:
Clamp Multimeter
Jaw Opening:
17.8mm
Frequency:
45Hz-66Hz
Safety Level:
1000V CAT III 600V CAT IV
Color:
Yellow
Calibration:
1-year calibration cycle
Packing:
Storage Case
+ −
  • Fluke T6-1000 Electrical Tester

    ৳ 87,500.00

    Request a Call Back

    •  Ask a Question

      Fluke T6-1000 Electrical Tester

      ৳ 87,500.00

      Ask a Question

        ... people are viewing this right now

        Share
      Guaranteed Safe Checkout
      Measurement Specifications
      Function Requires test leads Range Resolution Accuracy[1]
      FieldSense
      ac voltage true-rms
      No 1000 V 1 V ± (3 % + 3 counts) 45 Hz – 66 Hz[2][3]
      FieldSense
      ac current true-rms
      No 200.0 A 0.1 A ± (3% + 3 counts) 45 Hz – 66 Hz
      FieldSense
      frequency (Hz)
      No 45 Hz – 66 Hz 1 Hz ± (1% + 2 counts)[3]
      Volts ac true-rms Yes 1000 V 1 V ± (1.5% + 2 counts) 45 Hz – 66 Hz
      Volts dc Yes 1000 V 1 V ± (1% + 2 counts)
      Resistance Yes 2000 Ω 1 Ω ± (1% + 2 counts)
      Yes 20.00 kΩ 0.01 kΩ
      Yes 100.0 kΩ 0.1 kΩ
      Safety 1000 V CAT III
      600 V CAT IV
      Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
      Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
      Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

       

      General Specifications
      Calibration 1-year calibration cycle
      Dimensions 61.1 x 259.3 x 43.8 mm
      Jaw opening 17.8 mm
      Weight 0.35 kg (0.78 lb)
      Temperature Operating -10 °C to +50 °C (14 °F to 122 °F)
      Storage -30 °C to +60 °C (-22 °F to +140 °F)
      Altitude Operating 2,000 m (6,562 feet)
      Storage 10,000 m (32,808 feet)
      Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
      0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
      0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
      Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
      Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
      0.1 x (specified accuracy) / °C for <18°C or >28 °C
      Safety IEC/EN 61010-1: Pollution Degree 2
      Electromagnetic Environment IEC/EN 61326-1: Portable

      Based on 0 reviews

      0.00 Overall
      0%
      0%
      0%
      0%
      0%
      Be the first to review “Fluke T6-1000 Electrical Tester”

      Your email address will not be published. Required fields are marked *

      Reviews

      There are no reviews yet.

      SKU: 1790960849-371 Category:
      Close
      Close My Cart
      Close Wishlist
      Recently Viewed Close
      Close

      Close
      Navigation
      Categories