| Wiring connections | 1P2W, 1P3W, 3P3W, 3P4W | ||||||
|---|---|---|---|---|---|---|---|
| Measurements and parameters |
Voltage, Current, Frequency, Active power, Reactive power, Apparent power, Power factor(cosθ), Phase angle, Harmonics(THD-R/THD-F), Phase rotation | ||||||
| ACV | |||||||
| Range | 1000V | ||||||
| Accuracy | ±0.7%rdg±3dgt (40.0 to 70.0Hz) ±0.3%rdg±5dgt (70.1Hz to 1KHz) |
||||||
| Crest factor | 1.7 or less | ||||||
| ACA | |||||||
| Range | 40.00/400.0/1000A (3 range auto) | ||||||
| Accuracy | ±1.0%rdg±3dgt (40.0 to 70.0Hz) ±2.0%rdg±5dgt (70.1Hz to 1kHz) |
||||||
| Crest factor | 3 or less on 40.00A/400.0A range, 3 or less 1500A peak on 1000A range | ||||||
| Frequency | |||||||
| Display Range | 40.0 to 999.9Hz | ||||||
| Accuracy | ±0.3%rdg±3dgt | ||||||
| Active power | |||||||
| Range | 40.00/400.0/1000kW | ||||||
| Accuracy | ±1.7%rdg±5dgt (PF1, sine wave, 45 to 65Hz) | ||||||
| Apparent power | |||||||
| Range | 40.00/400.0/1000kVA | ||||||
| Accuracy | ±1dgt against each calculated value Sum: add errors of each channel, 3P3W: ±2dgt, 3P4W:±3dgt |
||||||
| Reactive power | |||||||
| Range | 40.00/400.0/1000kVar | ||||||
| Accuracy | ±1dgt against each calculated value Sum: add errors of each channel, 3P3W: ±2dgt, 3P4W:±3dgt |
||||||
| Power factor | |||||||
| Display Range | -1.000 to 0.000 to +1.000 | ||||||
| Accuracy | ±1dgt against each calculated value Sum: add errors of each channel, 3P3W: ±2dgt, 3P4W:±3dgt |
||||||
| Phase angle (1P2W only) | |||||||
| Display Range | -180.0 to 0.0 to +179.9 | ||||||
| Accuracy | Within ±3.0° | ||||||
| Harmonics RMS(Content rate) | |||||||
| Analysis order | 1st to 30th order | ||||||
| Accuracy | ±5.0%rdg ± 10dgt (1 to 10th) ±10%rdg ± 10dgt (11 to 20th) ±20%rdg ± 10dgt (21 to 30th) |
||||||
| Total harmonics THD-R/THD-F | |||||||
| Display Range | 0.0% to 100.0% | ||||||
| Accuracy | ±1dgt against the calculated results of each measured value | ||||||
| Phase rotation | ACV 80 to 1100V (45 to 65Hz) | ||||||
| Other functions | MAX/MIN/AVG/PEAK, Data hold, Bluetooth®, Backlight, Auto power off | ||||||
| General | |||||||
| Communication interface |
Bluetooth® 5.0 | ||||||
| Power source | LR6 (AA) (1.5V) ×2 | ||||||
| Continuous measuring time |
Approx. 58 hours | ||||||
| Conductor size | φ75 mm max. (busbar of 80mm × 30mm) | ||||||
| Dimension / Weight | 283(L) × 143(W) × 50(D) mm / Approx. 590g (including batteries) | ||||||
| Applicable standards | IEC 61010-1, IEC 61010-2-032, IEC 61326-1,2-2 ClassB CAT Ⅳ 600V / CAT Ⅲ 1000V Pollution degree 2 |
||||||
| Accessories | 7290 (Test leads) 9198 (Carrying Case) LR6(AA)×2, Instruction Manual |
||||||
|
|
|