৳ 0.00
AC Measurement

34 5790B AC Measurement Standard

34 5790B AC Measurement Standard
The 5790B covers an alternating voltage range of 600 μV to 1000 V, and a frequency range of 10 Hz to 1 MHz. Wideband voltage options extend the frequency range to 30 or 50 MHz.
The 5790B AC Measurement Standard is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you would expect from a thermal transfer standard with the ease of use of a digital multimeter.
The 5790B may be used alone as a measurement device or as a transfer standard when compared to an external dc source. In either case, the normally tedious switching and calculations are performed automatically by the 5790B, and the resulting ac/dc difference is displayed directly on the easy-to-read 6.5-inch full-color capacitive touch screen display.
Key Features:
Get the infrared troubleshooting power you need.
| Summary Specifications | |||||
| AC and dc voltage |
|
||||
| Inputs | Input 1: 600 µV to 1000 V (5% over-range)
Input 2: 600 µV to 1000 V (5% over-range) Aux input: 250 mV to 500 mV WB input: <7 V rms wideband |
||||
| Warm-up time | 30 minutes | ||||
| Relative humidity | Operating: 45% to 50 °C 75% to 45 °C 95% to 30 °C
Storage: <95% non-condensing |
||||
| Altitude | Operating: 3,050 meters (10,000 feet)
Non-operating: 12,200 meters (40,000 feet) |
||||
| Temperature | Operating: 0 °C to °50 C
Calibration: 15 °C to 35 °C Storage: -40 °C to 70 °C |
||||
| Electromagnetic Compatibility (EMC) | |||||
| International | IEC 61326-1: Controlled Electromagnetic Environment – CISPR 11: Group 1, Class A | ||||
| Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) | ||||
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | ||||
| Surge | ANSI C62.41-1980, Category A | ||||
| Reliability | MIL-T-2880D, paragraph 3.13.3 | ||||
| General Specifications | |||||
| Dimensions | Height: 17.8 cm (7 in) standard rackmount + 1.5 cm (0.6 in)
Width: 43.2 cm (17 in) Depth: 62 cm (24.8 in) |
||||
| Maximum power requirements | 5790B: 100 VA | ||||
| Weight | 5790B: 24 kg (53 lb)
With wideband: 24.5 kg (54 lb) |
||||
| Line power | 50 Hz or 60 Hz; 100 V – 120 V, 220 V – 240 V
100V, 110 V, 115 V, 120 V, 200 V, 220 V, 230 V, 240 V |
||||
| Safety | Complies with UL1244 and IEC 348-1976 and IEC 1010 and CSA C22.2 No. 231 and ANSI/ISA S82 | ||||
| Remote interfaces | RS-232, IEEE-488 | ||||
| Confidence level | 99% unless otherwise specified | ||||
| 5790B/AF | |||||
| The 5790B/AF has enhanced absolute accuracy to ± 0.23 % of voltage (1 year after factory calibration, 23 °C ± 3 °C, at 95 % confidence level) at 50 MHz and 223.61 mV, using a serialized one meter cable, characterized at that point for RF power meter 0 dBm reference output measurement. In the RF power measurement mode, the accuracy is specified to the end of the serialized cable with a curve fit for the other ranges and frequencies that is a first-order correction for cable loss. | |||||
Includes:
| Model Name | Description |
|---|---|
| 5790B | AC Measurement Standard |
| 5790B/3 | AC Measurement Standard +30 MHz Wideband Option |
| 5790B/5 | AC Measurement Standard _ 50 MHz Wideband Option |
| 5790B/AF | AC Measurement Standard + 50 MHz Wideband Option Calibrated with WB Cable |
| A40B-001MA | 1 milliamp Current Shunt |
| A40B-010MA | 10 milliamp Current Shunt |
| A40B-020MA | 20 milliamp Current Shunt |
| A40B-050MA | 50 milliamp Current Shunt |
| A40B-100mA | 100 milliamp Current Shunt |
| A40B-200mA | 200 milliamp Current Shunt |
| A40B-500mA | 500 milliamp Current Shunt |
| A40B-1A | 1 amp Current Shunt |
| A40B-2A | 2 amp Current Shunt |
| A40B-5A | 5 amp Current Shunt |
| A40B-10A | 10 amp Current Shunt |
| A40B-20A | 20 amp Current Shunt |
| A40B-50A | 50 amp Current Shunt |
| A40B-100A | 100 amp Current Shunt |
| Accessory | Description |
|---|---|
| 5790B/5 WB Cable | Cable, 50 Ohm Wideband Cable for 50 MHz Measurements |
| 57XX/CASE | Transit Case for 57XXA Series |
| Y5737 | 5790B and 5700A/5720A Rack Mount Kit. Includes 24 in. slides that allow for side ventilation |
| A40B-LEAD/4MM | N to 4 mm double banana connector |
| A40B-LEAD/N | N Male to N Male lead |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
Key Features:
Get the infrared troubleshooting power you need.
Det14c and Det24c Earth Resistance Clamp Testers the most advanced megger Clamp Testers that you can depend on.
The DET14C and DET24C represent a new generation of earth/ground clamp-on resistance testers. These instruments induce a test current into earth systems and measure ground resistance in multi ground installations without needing to disconnect the ground. They offer market-leading access, advanced features, simple operation and CAT IV 600 V safety protection.
The elliptical shaped head design offers improved access to cables and earth straps in space-constrained locations. The clamp head accommodates up to 37 mm diameter cable and 50 mm earth tapes making them suitable for use in power stations, substations, towers and many more facilities.
The Megger LRCD200 series is the latest generation of combined non-tripping loop tester and RCD test instruments that provide simple, affordable and flexible test tools for electrical contractors testing energized circuits.
Reviews
There are no reviews yet.