৳ 0.00

Fluke 116 Digital HVAC Multimeter

Fluke 116 Digital HVAC Multimeter
Fluke 116 Digital HVAC Multimeter the latest brand new Fluke tools. That always provides an accurate result that you can depend on. The main & important thing about Fluke 116 is that provides microamps to test flame sensors.
It is one of the unique multimeters from Fluke adding meters because it is the single-handed one that can perform microamps. That’s easily reached if you compulsion to test flame sensors. The Fluke 116 is after that the by yourself one the 179 that can law temperature (taking place to 400 degrees Celsius or 752 degrees F). It comes taking into account an outdoor test explore for that.
Since it measures unaccompanied microamperes, the maximum current it can handle is 600A. But Fluke 116 easily can in front of payment resistance, continuity, frequency, capacitance, and test diodes. It has LoZ or low impedance, thus it can ignore ghost voltages from adjacent wires or energized circuits.
The Fluke 116 has a 6000-include readout and a white backlight. It can display an analog bar graph of the data. There is a retaining button to preserve the latest reading on the screen, as nimbly as a min/max/average undertaking to stamp album fluctuations.
Fluke Digital HVAC Multimeter The Fluke 116 measures resistance, continuity, frequency, and capacitance. Why do you use another one? Buy from Tools Bangladesh to get the best result for your work spot.
| Specifications | ||
| Maximum voltage between any terminal and earth ground | 600 V | |
| Surge protection | 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 | |
| Display | Digital: 6,000 counts, updates 4 per second | |
| Bar graph | 33 segments, updates 32 per second | |
| Operating temperature | -10°C to + 50°C | |
| Storage temperature | -40°C to + 60°C | |
| Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
| Battery life | 400 hours typical, without backlight | |
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| Auto volts | Range/resolution | 600.0 V / 0.1 V |
| Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) | |
| AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
| AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
| Continuity | Range/resolution | 600 Ω / 1 Ω |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. | |
| Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
| Accuracy | 0.9% + 1 | |
| Range/Resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5% + 2 | |
| Diode Test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% + 2 | |
| Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
| Accuracy | 1.9% + 2 | |
| Range/resolution | > 1000 μF | |
| Accuracy | 5% + 20% | |
| Lo-Z Capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% + 2 typical | |
| Temperature² (Type-K thermocouple) | Range/resolution | -40°C to 400°C / 0.1°C |
| Accuracy | 1% + 10² | |
| Range/resolution | -40°F to 752°F / 0.2°F | |
| Accuracy | 1% + 18² | |
| AC μA true-rms (45 Hz to 500 Hz) | Range/resolution | 600.0 μA / 0.1 μA |
| Accuracy | 1.5% + 3 | |
| DC μamps | Range/resolution | 600.0 μA / 0.1 μA |
| Accuracy | 1.0% + 2 | |
| Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz |
| Accuracy | 0.1% + 2 | |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||
| Mechanical and General Specifications | ||
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
| Weight | 550 g | |
| Warranty | 3 years | |
Cases (4)
Other (2)
Clips (2)
Lights (2)
Probes (1)
Visual IR thermometers (1)
Test leads (4)
| 0% | ||
| 0% | ||
| 0% | ||
| 0% | ||
| 0% |