5322A Electrical Safety Tester Calibrator
5322A Electrical Safety Tester Calibrator
The 5322A combines many functions into a single instrument, replacing discrete resistors, decade boxes and other custom solutions commonly used to calibrate electrical testers. This single-box solution speeds and simplifies calibration because users only need to learn, operate and maintain one calibrator rather than multiple instruments.
The 5322A Electrical Tester Calibrator helps calibration technicians comply with new regulatory standards up to four times faster than with traditional manual, multiple-product methods. The 5322A replaces the 5320A Electrical Tester Calibrator.
Key Features:
Get the infrared troubleshooting power you need.
Specifications confidence level | 99% |
Specifications interval | 1 year |
Power line | 115/230 V ac (50/60 Hz) +10 % / -14 %, with the maximum voltage difference between neutral and protective earth not exceeding 15 V. Operation with power line between -10 % and -14 % has limitations in burden current for voltage outputs. See AC/DC Voltage Calibrator (VLC option) below. |
Power consumption | 1250 VA maximum |
Fuse protection | AC mains input: 2 A, 250 V for 230 V, time delay (T2L250 V – 5 mm x 20 mm) 4 A, 250 V for 115 V, time delay (T4L250 V – 5 mm x 20 mm) RCD input: 3.15 A, 250 V, fast (F3.15H250 V – 5 mm x 20 mm) Meter amps (A) input: 20 A, 500 V, time delay (F20H500 V – 6.3 mm x 32 mm) Loop/Line impedance input: 4 A, 500 V, time delay (T4H500 V – 6.3 mm x 32 mm) Leakage current input: 100 mA, 250 V, fast (F100 mL250 V – 5 mm x 20 mm) |
Environment | |
---|---|
Warm-up time | 15 minutes |
Temperature performance | Operating temperature: 18 °C to 28 °C Calibration temperature (tcal): 23 °C Temperature coefficient for temperatures outside of tcal ± 5 °C is 0.1 / °C of the specification, for temperatures between 5 °C to 40 °C. Storage temperature: -10 °C to 50 °C Storage recovery time: Typically <24 hours at operating temperature |
Relative humidity (operating) | <80 % to 28 °C (resistance outputs >10 GΩ specified for <70 % to 28 °C) |
Relative humidity (storage) | 90 % non-condensing 0 °C to 50 °C |
Altitude | Operating: 3050 m (10 000 ft) Storage: 12 200 m (40 000 ft) |
Dimensions and weight | |
---|---|
Dimensions | 430 mm x 555 mm x 170 mm (16.9 in x 21.8 in x 6.7 in) |
Weight | 20 kg (44.1 lb) |
Compliance | |
---|---|
Safety | Mains: IEC 61010-1: Overvoltage category II, pollution degree 2 Measurement: IEC 61010-2-030: 5000 V (not category rated) |
Electromagnetic compatibility (EMC) | International:
Korea (KCC):
USA (FCC):
|
Low resistance source | |
---|---|
Range | 100 mΩ to 10 kΩ + 10 mΩ single value selection, dc and line frequency (50/60 Hz) |
1.5 kV high resistance source (DC only) | |
---|---|
Range | 10 kΩ to 10 GΩ + 100 GΩ single value selection |
5.5 kV high resistance source (DC only) (5322A with /5 option) | |
---|---|
Range | 10 kΩ to 100 GΩ |
Test voltage measurement | |
---|---|
Range | 0 V dc to 5500 V dc |
Ground bond resistance source | |
---|---|
Resistance mode | |
Range | 1 mΩ to 1700 Ω, dc and line frequency (50/60 Hz) |
Line/loop impedance source | |
---|---|
Range | 25 mΩ to 1700 Ω |
Correction manual/scan mode | |
---|---|
Residual impedance range | 0 Ω to 10 Ω |
Resolution | 1 mΩ |
Correction COMP mode (active loop compensation) (5322AVLC Option) | |
---|---|
Maximum compensated impedance | 0 Ω to 2 Ω |
Leakage current source | |
Range | 0.1 to 30 mA |
Test voltage | Passive mode: 60 V ac to 250 V ac rms Differential mode: 60 V ac to 250 V ac rms Substitute mode:10 V ac to 250 V ac rms Active mode (5322A/VLC only)1: 50 V ac to 100 V ac rms |
Uncertainty | Passive mode: ± (0.3% setting + 2 μA) Differential mode: ± (0.3% setting + 2 μA) Test uncertainty can be influenced by power line voltage instability Substitute mode: ± (0.3% setting + 2 μA) Active mode (5322A/VLC only)1: ± (0.3% setting + 1 μA) |
1 The Active Mode outputs are synchronized with the ac mains frequency to suppress interference between the calibrator and external noise sources. | |
Human body simulation (for substitute leakage currently only | Resistance range: 0 Ω to 10 000 Ω Resolution: 1 Ω |
Includes:
Model Name | Description |
---|---|
5322A | Multifunction Electrical Tester Calibrator with 1.5 kV Resistance |
5322A/5 | Multifunction Electrical Tester Calibrator with 5 kV High Voltage Resistance Outputs |
5322A/VLC | Calibrator with 1.5 kV Resistance, 600 V Source, Voltage Loop Compensation |
5322A/40 | Calibrator with 1.5 kV Resistance and 40 kV Probe |
5322A/5/VLC | Calibrator with 5 kV Resistance, 600 V Source, Voltage Loop Compensation |
5322A/VLC/40 | Calibrator with 1.5 kV Resistance, 600 V Source, Voltage loop Compensation and 40 kV Probe |
5322A/5/40 | Calibrator with 5 kV Resistance, and 40 kV Probe |
5322A/5/VLC/40 | Calibrator with 5 kV Resistance, 600 V Source, Voltage Loop Compensation and 40 kV Probe |
Includes:
Accessory | Description |
---|---|
5322A-LOAD | High Voltage Resistor Load for 5322A |
Y5320A | Rack Mount Kit for 5322A – Sliding |
5322A/CASE | Transit Case for 5322A (without 5322A-LOAD) |