      5322A Electrical Safety Tester Calibrator

      ৳ 0.00

      Ask a Question

        ... people are viewing this right now

        Share
      Guaranteed Safe CheckoutTrust

      The 5322A combines many functions into a single instrument, replacing discrete resistors, decade boxes and other custom solutions commonly used to calibrate electrical testers. This single-box solution speeds and simplifies calibration because users only need to learn, operate and maintain one calibrator rather than multiple instruments.

      The 5322A Electrical Tester Calibrator helps calibration technicians comply with new regulatory standards up to four times faster than with traditional manual, multiple-product methods. The 5322A replaces the 5320A Electrical Tester Calibrator.

      Fluke PTi120 Pocket Thermal Camera

      Key Features:

      Get the infrared troubleshooting power you need.

      • Automatically organize and file thermal images with Fluke Connect Asset Tagging
      • Fully radiometric thermal imager gives you measurement data to the pixel with 120 x 90 infrared resolution (10,800 pixels)
      • 5” LCD touchscreen display for easy troubleshooting
      • -20 °C to +150 °C temperature measurement range
      • Six color palettes
      • Can withstand drop up to 1 meter
      • IP 54 enclosure rating

      Specifications: 5322A Electrical Safety Tester Calibrator

      Specifications confidence level99%
      Specifications interval1 year
      Power line

      115/230 V ac (50/60 Hz) +10 % / -14 %, with the maximum voltage difference between neutral and protective earth not exceeding 15 V. Operation with power line between -10 % and -14 % has limitations in burden current for voltage outputs. See AC/DC Voltage Calibrator (VLC option) below.

      Power consumption1250 VA maximum
      Fuse protection

      AC mains input: 2 A, 250 V for 230 V, time delay (T2L250 V – 5 mm x 20 mm) 4 A, 250 V for 115 V, time delay (T4L250 V – 5 mm x 20 mm)

      RCD input: 3.15 A, 250 V, fast (F3.15H250 V – 5 mm x 20 mm)

      Meter amps (A) input: 20 A, 500 V, time delay (F20H500 V – 6.3 mm x 32 mm)

      Loop/Line impedance input: 4 A, 500 V, time delay (T4H500 V – 6.3 mm x 32 mm)

      Leakage current input: 100 mA, 250 V, fast (F100 mL250 V – 5 mm x 20 mm)

      Environment
      Warm-up time15 minutes
      Temperature performance

      Operating temperature: 18 °C to 28 °C

      Calibration temperature (tcal): 23 °C

      Temperature coefficient for temperatures outside of tcal ± 5 °C is 0.1 / °C of the specification, for temperatures between 5 °C to 40 °C.

      Storage temperature: -10 °C to 50 °C

      Storage recovery time: Typically <24 hours at operating temperature

      Relative humidity (operating)<80 % to 28 °C (resistance outputs >10 GΩ specified for <70 % to 28 °C)
      Relative humidity (storage)90 % non-condensing 0 °C to 50 °C
      Altitude

      Operating: 3050 m (10 000 ft)

      Storage: 12 200 m (40 000 ft)

      Dimensions and weight
      Dimensions430 mm x 555 mm x 170 mm (16.9 in x 21.8 in x 6.7 in)
      Weight20 kg (44.1 lb)
      Compliance
      Safety

      Mains: IEC 61010-1: Overvoltage category II, pollution degree 2

      Measurement: IEC 61010-2-030: 5000 V (not category rated)

      Electromagnetic compatibility (EMC)

      International:

      • IEC 61326-1: Basic electromagnetic environment
      • CISPR 11: Group 1, Class A
        • Group 1: Equipment has intentionally generated and/or uses conductively-coupled radiofrequency energy that is necessary for the internal function of the equipment itself.
        • Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.

          Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.

      Korea (KCC):

      • Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

      USA (FCC):

      • 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

      Electrical specifications

      Low resistance source
      Range100 mΩ to 10 kΩ + 10 mΩ single value selection, dc and line frequency (50/60 Hz)

       

      1.5 kV high resistance source (DC only)
      Range10 kΩ to 10 GΩ + 100 GΩ single value selection
      5.5 kV high resistance source (DC only) (5322A with /5 option)
      Range10 kΩ to 100 GΩ
      Test voltage measurement
      Range0 V dc to 5500 V dc
      Ground bond resistance source
      Resistance mode
      Range1 mΩ to 1700 Ω, dc and line frequency (50/60 Hz)
      Line/loop impedance source
      Range25 mΩ to 1700 Ω
      Correction manual/scan mode
      Residual impedance range0 Ω to 10 Ω
      Resolution1 mΩ
      Correction COMP mode (active loop compensation) (5322AVLC Option)
      Maximum compensated impedance0 Ω to 2 Ω
      Leakage current source
      Range0.1 to 30 mA
      Test voltage

      Passive mode: 60 V ac to 250 V ac rms

      Differential mode: 60 V ac to 250 V ac rms

      Substitute mode:10 V ac to 250 V ac rms

      Active mode (5322A/VLC only)1: 50 V ac to 100 V ac rms

      Uncertainty

      Passive mode: ± (0.3% setting + 2 μA)

      Differential mode: ± (0.3% setting + 2 μA)

      Test uncertainty can be influenced by power line voltage instability

      Substitute mode: ± (0.3% setting + 2 μA)

      Active mode (5322A/VLC only)1: ± (0.3% setting + 1 μA)

       

      1 The Active Mode outputs are synchronized with the ac mains frequency to suppress interference between the calibrator and external noise sources.

      Human body simulation (for substitute leakage currently only

      Resistance range: 0 Ω to 10 000 Ω

      Resolution: 1 Ω

      5322A Electrical Safety Tester Calibrator

      Includes:

      Model NameDescription
      5322A

      Multifunction Electrical Tester Calibrator with 1.5 kV Resistance

      5322A/5

      Multifunction Electrical Tester Calibrator with 5 kV High Voltage Resistance Outputs

      5322A/VLC

      Calibrator with 1.5 kV Resistance, 600 V Source, Voltage Loop Compensation

      5322A/40

      Calibrator with 1.5 kV Resistance and 40 kV Probe

      5322A/5/VLC

      Calibrator with 5 kV Resistance, 600 V Source, Voltage Loop Compensation

      5322A/VLC/40

      Calibrator with 1.5 kV Resistance, 600 V Source, Voltage loop Compensation and 40 kV Probe

      5322A/5/40

      Calibrator with 5 kV Resistance, and 40 kV Probe

      5322A/5/VLC/40

      Calibrator with 5 kV Resistance, 600 V Source, Voltage Loop Compensation and 40 kV Probe

       

      5322A Electrical Safety Tester Calibrator

      Includes:

      Accessories common to all models:

      AccessoryDescription
      5322A-LOAD

      High Voltage Resistor Load for 5322A

      Y5320A

      Rack Mount Kit for 5322A – Sliding

      5322A/CASE

      Transit Case for 5322A (without 5322A-LOAD)

      Based on 0 reviews

      0.00 Overall
      0%
      0%
      0%
      0%
      0%
      Be the first to review “5322A Electrical Safety Tester Calibrator”

      Your email address will not be published. Required fields are marked *

      Reviews

      There are no reviews yet.

      SKU: tools109 Category:
      Close
      Close My Cart
      Close Wishlist
      Recently Viewed Close
      Close

      Close
      Navigation
      Categories