৳ 0.00
Fluke 317 Clamp Meters
Fluke 317 Clamp Meters
Fluke 317 and 319 are designed gone ergonomic concepts, shaped to fit your hand and to admission tight a skin condition easily. These small and rugged clamp meters are ideally suited for current measurements in the works to 1000 A (319) in tight cable compartments.
The Fluke 317 as well as come going on following than the money for AC/DC current measurements and has a highly developed conclusive for large quantity numb 40 A. In accessory to a compact package once a hermetic feature set, the Fluke 319 moreover equip subsequent to In-hurry current and Frequency functions for psychoanalysis motors, lighting, etc.
Fluke 317 and 319 Clamp Meters are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. Affordable this Fluke model buy now from Tools Bangladesh.
General specifications | |
Digital display | 6000 count resolution |
Low battery Indication | Displays a signal when the batteries are below their required voltage |
Power source | Three AAA IEC LR03 batteries |
Clamp opening size | 1.45 in (37 mm) |
Jaw diameter | 1.45 in (37 mm) |
Dimensions (L x W x H) | 6.39 x 2.29 x 1.20 in |
(162.4 x 58.25 x 30.5 mm) | |
Weight | Approximately 13.5 oz (384 g) (batteries included) |
Auto range | Available in Ohms |
Safety | CE |
EN/IEC 61010-1 and IEC 61010-2-032 | |
Measurement Category: 600V CAT III |
317 Electrical specifications | ||
Current AC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
2.5% ±8 digit (60-500 Hz) {40 A} | ||
1.5% ±5 digit (50-60 Hz) {600 A} | ||
2.5% ±5 digit (60-500 Hz) {600 A} | ||
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A | |
AC response | rms | |
Current DC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ±6 digit (40 A) | |
1.5% ±5 digit (600 A) | ||
Voltage AC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digit (20-500Hz) | |
AC response | rms | |
Voltage DC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1% ±4 digit | |
Resistance | Range | 400.0 Ω, 4000 Ω |
Resolution | 0.1 Ω, 1 Ω | |
Accuracy | 1% ±5 digit | |
Continuity | ≤ 30 Ω | |
Inrush | Integration time | N/A |
Frequency | Range | N/A |
Accuracy | N/A | |
Trigger Level | N/A |
319 Electrical specifications | ||
Current AC | Range | 40.00 A, 600.0 A, 1000 A |
Resolution | 0.01 A, 0.1 A, 1 A | |
Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
2.5% ±8 digit (60-500 Hz) {40 A} | ||
1.5% ±5 digit (50-60 Hz) {600/1000 A} | ||
2.5% ±5 digit (60-500 Hz) {600/1000 A} | ||
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A | |
AC response | rms | |
Current DC | Range | 40.00 A, 600.0 A, 1000 A |
Resolution | 0.01 A, 0.1 A, 1 A | |
Accuracy | 1.6% ±6 digit (40 A) | |
1.5% ±5 digit (600/1000 A) | ||
Voltage AC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digit (20-500Hz) | |
AC response | rms | |
Voltage DC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1% ±4 digit | |
Resistance | Range | 400.0 Ω |
4000 Ω | ||
Resolution | 0.1 Ω | |
1 Ω | ||
Accuracy | 1% ±5 digit | |
Continuity | ≤ 30 Ω | |
Inrush | Integration time | 100 ms |
Frequency | Range | 5.0 – 500.0 Hz |
Accuracy | 0.5% ±5 digit | |
Trigger Level | 10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A | |
The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C) Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C. True rms for ac V and ac A accuracy is specified from 5% to 100% of range. |
Environmental specifications | |
Operating temperature | 14°F to 122°F (-10 °C to 50 °C) |
Storage temperature | -40 °F to 140 °F (-40 °C to 60 °C) |
Operating humidity | Non-condensing (< 50 °F) (< 10 °C) |
90% RH (50 °F to 86 °F) (10 °C to 30 °C) | |
75% RH (86 °F to 104 °F) (30 °C to 40 °C) | |
45% RH (104 °F to 122 °F) (40 °C to 50 °C) | |
(Without condensation) | |
Operating altitude | 1 mile (2000 meters) above mean sea level |
Storage altitude | 7 miles (12,000 meters) above mean sea level |
IP Rating | IP40 |
Vibration requirements | Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis |
Drop test requirements | 3 ft (1 m) drop test, six sides, oak floor |
EMI, RFI, EMC | Instrument unspecified for use in EMC field ≥ 0.1 V/m |
Temperature coefficients | 0.1x (specified accuracy)/ °C |
(<64 °F or > 82° F) | |
(<18 °C or > 28 °C) |
Fluke 317/319The Fluke 317 and 319 are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. The Meter ships with:
These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments. The Fluke 317and 319 also offer AC/DC current measurements and has a higher resolution for loads below 40 A.
In addition to a compact package with a strong feature set, the Fluke 319 also equip with In-rush current and Frequency functions for testing motors, lighting, etc
Clips (1)
Lights (1)
Test leads (1)
0% | ||
0% | ||
0% | ||
0% | ||
0% |
Reviews