৳ 0.00
22 Fluke 17B+ Digital Multimeter
22 Fluke 17B+ Digital Multimeter
The Fluke 17B+ digital multimeter is the best qualified for you. When you distressed feeling to accomplish the ably-behaved & accurate outcome
Fluke 17B+ digital multimeter easily can pretend Voltage, resistance, continuity, capacitance. The most important things about Fluke 17B+ multimeter always have the funds for the right result in any mood. More speedily & safely you can perform anything that you are looking for.
This meter accuracy is specified for 1 year after calibration, at full of zip temperatures of 18 C to 28 C, relative humidity at 0% to 75%. Accuracy specifications acceptance to the form of (% of Reading + Number of Least Significant Digits).
The Fluke is a very productive and compact, easy to use tool that delivers safe, reliable measurements. You can take out it with your reasonable price in Bangladesh through Dusk Technology BD. One time delivery service.
Function | Range | Resolution | Accuracy | |
AC volts (40 Hz to 500Hz)1 | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 1.0% + 3 | |
DC volts | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 0.5% + 3 | |
AC millivolts | 400.0 mV | 0.1 mV | 3.0% + 3 | |
DC millivolts | 400.0 mV | 0.1 mV | 1.0% + 10 | |
Diode test2 | 2.000 V | 0.001 V | 10% | |
Resistance (Ohms) | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | 0.5% + 3 0.5% + 2 0.5% + 2 0.5% + 2 0.5% + 2 1.5% + 3 | |
Capacitance3 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF | 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 | |
Frequency1 Hz (10 Hz – 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | 0.1% + 3 | |
Duty Cycle1 | 1% to 99% | 0.1% | 1% typical 4 | |
AC current μA (40 Hz to 400 Hz) | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5% + 3 | |
AC current mA (40 Hz to 400 Hz) | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5% + 3 | |
AC current A (40 Hz to 400 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5% + 3 | |
DC current μA | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5% + 3 | |
DC current mA | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5% + 3 | |
DC current A | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5% + 3 | |
Temperature | 50 °C- 400 °C 0 °C- 50 °C -55 °C- 0 °C | 0.1C | 2% ±1 °C ±2 °C 9% ±2 °C | |
Backlight | – | – | Yes | |
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). 4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90%. |
Function | Overload protection | Input impedance (Nominal) | Common mode rejection ratio | Normal mode rejection ratio |
AC volts | 1000 V 1 | >10 MΩ <100 pF | >60 dB at dc, 50 Hz or 60 Hz | – |
AC millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | – |
DC volts | 1000 V 1 | >10 MΩ <100 pF | >100 dB at dc, 50 Hz or 60 Hz | >60 dB at 50 Hz or 60 Hz |
DC millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | – |
1 106 V Hz Max |
General specifications | |
Maximum voltage between any terminal and earth ground | 1000 V |
Display (LCD) | 4000 counts, updates 3/sec |
Battery type | 2 AA, NEDA 15A, IEC LR6 |
Battery life | 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.) |
Temperature | |
Operating | 0 °C to 40 °C |
Storage | -30 °C to 60 °C |
Relative humidity | |
Operating humidity | Non-condensing (<10°C) ≤90% RH at 10 °C to 30 °C ≤75% RH at 30 °C to 40 °C |
40 MΩ range ≤80% RH at 10 °C to 30 °C ≤70% RH at 30 °C to 40 °C | |
Altitude | |
Operating | 2000 m |
Storage | 12,000 m |
Temperature coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
Fuse protection for current inputs | 440 mA, 1000 V Fast Fuse, Fluke specified part only. 11A, 1000V Fast Fuse, Fluke specified part only. |
Size (H x W x L) | 183 x 91 x 49.5 mm |
Weight | 455 g |
IP rating | IP 40 |
Safety | IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2 |
Electromagnetic environment | IEC 61326-1: Portable |
Electromagnetic compatibility | Applies to use in Korea only |
0% | ||
0% | ||
0% | ||
0% | ||
0% |
Reviews