      The 5790B covers an alternating voltage range of 600 μV to 1000 V, and a frequency range of 10 Hz to 1 MHz. Wideband voltage options extend the frequency range to 30 or 50 MHz.

      The 5790B AC Measurement Standard is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you would expect from a thermal transfer standard with the ease of use of a digital multimeter.

      The 5790B may be used alone as a measurement device or as a transfer standard when compared to an external dc source. In either case, the normally tedious switching and calculations are performed automatically by the 5790B, and the resulting ac/dc difference is displayed directly on the easy-to-read 6.5-inch full-color capacitive touch screen display.

      Fluke PTi120 Pocket Thermal Camera

      Key Features:

      Get the infrared troubleshooting power you need.

      • Automatically organize and file thermal images with Fluke Connect Asset Tagging
      • Fully radiometric thermal imager gives you measurement data to the pixel with 120 x 90 infrared resolution (10,800 pixels)
      • 5” LCD touchscreen display for easy troubleshooting
      • -20 °C to +150 °C temperature measurement range
      • Six color palettes
      • Can withstand drop up to 1 meter
      • IP 54 enclosure rating

      Specifications: 5790B AC Measurement Standard

      Summary Specifications
      AC and dc voltage
         
      Best 99%, absolute specification:  ± 24 ppm (one year, 23 °C to ± 5 °C
      Inputs

      Input 1: 600 µV to 1000 V (5% over-range)

      Input 2: 600 µV to 1000 V (5% over-range)

      Aux input: 250 mV to 500 mV

      WB input: <7 V rms wideband

      Warm-up time 30 minutes
      Relative humidity

      Operating: 45% to 50 °C 75% to 45 °C 95% to 30 °C

      Storage: <95% non-condensing

      Altitude

      Operating: 3,050 meters (10,000 feet)

      Non-operating: 12,200 meters (40,000 feet)

      Temperature

      Operating: 0 °C to °50 C

      Calibration: 15 °C to 35 °C

      Storage: -40 °C to 70 °C

      Electromagnetic Compatibility (EMC)
      International IEC 61326-1: Controlled Electromagnetic Environment – CISPR 11: Group 1, Class A
      Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
      USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
      Surge ANSI C62.41-1980, Category A
      Reliability MIL-T-2880D, paragraph 3.13.3
      General Specifications
      Dimensions

      Height: 17.8 cm (7 in) standard rackmount + 1.5 cm (0.6 in)

      Width: 43.2 cm (17 in)

      Depth: 62 cm (24.8 in)

      Maximum power requirements

      5790B: 100 VA

      Weight

      5790B: 24 kg (53 lb)

      With wideband: 24.5 kg (54 lb)

      Line power

      50 Hz or 60 Hz; 100 V – 120 V, 220 V – 240 V

      100V, 110 V, 115 V, 120 V, 200 V, 220 V, 230 V, 240 V

      Safety Complies with UL1244 and IEC 348-1976 and IEC 1010 and CSA C22.2 No. 231 and ANSI/ISA S82
      Remote interfaces RS-232, IEEE-488
      Confidence level 99% unless otherwise specified
      5790B/AF
        The 5790B/AF has enhanced absolute accuracy to ± 0.23 % of voltage (1 year after factory calibration, 23 °C ± 3 °C, at 95 % confidence level) at 50 MHz and 223.61 mV, using a serialized one meter cable, characterized at that point for RF power meter 0 dBm reference output measurement. In the RF power measurement mode, the accuracy is specified to the end of the serialized cable with a curve fit for the other ranges and frequencies that is a first-order correction for cable loss.  

      5790B AC Measurement Standard

      Includes:

      Model Name Description
      5790B

      AC Measurement Standard

      5790B/3

      AC Measurement Standard +30 MHz Wideband Option

      5790B/5

      AC Measurement Standard _ 50 MHz Wideband Option

      5790B/AF

      AC Measurement Standard + 50 MHz Wideband Option Calibrated with WB Cable

      A40B-001MA

      1 milliamp Current Shunt

      A40B-010MA

      10 milliamp Current Shunt

      A40B-020MA

      20 milliamp Current Shunt

      A40B-050MA

      50 milliamp Current Shunt

      A40B-100mA

      100 milliamp Current Shunt

      A40B-200mA

      200 milliamp Current Shunt

      A40B-500mA

      500 milliamp Current Shunt

      A40B-1A

      1 amp Current Shunt

      A40B-2A

      2 amp Current Shunt

      A40B-5A

      5 amp Current Shunt

      A40B-10A

      10 amp Current Shunt

      A40B-20A

      20 amp Current Shunt

      A40B-50A

      50 amp Current Shunt

      A40B-100A

      100 amp Current Shunt

      Accessories common to all models:

      Accessory Description
      5790B/5 WB Cable

      Cable, 50 Ohm Wideband Cable for 50 MHz Measurements

      57XX/CASE

      Transit Case for 57XXA Series

      Y5737

      5790B and 5700A/5720A Rack Mount Kit. Includes 24 in. slides that allow for side ventilation

      A40B-LEAD/4MM

      N to 4 mm double banana connector

      A40B-LEAD/N

      N Male to N Male lead

      Based on 0 reviews

      0.00 Overall
      0%
      0%
      0%
      0%
      0%
      Be the first to review “5790B AC Measurement Standard”

      Your email address will not be published. Required fields are marked *

      Reviews

      There are no reviews yet.

      SKU: tools110 Category:
      Close
      Close My Cart
      Close Wishlist
      Recently Viewed Close
      Close

      Close
      Navigation
      Categories